| EBSX11P50DG / ERLA11D2V3 | EBSX11P30DG / ERLA11DAV3 | EBSX11P30DG / ERLA11D2V3 | EBSX11P50DG / ERLA11DAV3 | EBSX11P30DF / ERLA11DAV3 | EBSX11P50DF / ERLA11DAV3 | EBSX11P30DF / ERLA11D2V3 | EBSX11P50DF / ERLA11D2V3 | EBSX16P50DG / ERLA14D2V3 | EBSX16P30DG / ERLA14DAV3 | EBSX16P30DG / ERLA14D2V3 | EBSX16P50DG / ERLA14DAV3 | EBSX16P30DF / ERLA14DAV3 | EBSX16P50DF / ERLA14DAV3 | EBSX16P30DF / ERLA14D2V3 | EBSX16P50DF / ERLA14D2V3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Внутренний блок | EBSX11P50DG | EBSX11P30DG | EBSX11P30DG | EBSX11P50DG | EBSX11P30DF | EBSX11P50DF | EBSX11P30DF | EBSX11P50DF | EBSX16P50DG | EBSX16P30DG | EBSX16P30DG | EBSX16P50DG | EBSX16P30DF | EBSX16P50DF | EBSX16P30DF | EBSX16P50DF | ||||
| Теплопроизводительность | Ном. | кВт | 10.6 (1) | 10.6 (1) | 10.6 (1) | 10.6 (1) | 10.6 (1) | 10.6 (1) | 10.6 (1) | 10.6 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | ||
| Холодопроизводительность | Ном. | кВт | 11.2 (2) | 11.2 (2) | 11.2 (2) | 11.2 (2) | 11.2 (2) | 11.2 (2) | 11.2 (2) | 11.2 (2) | 12.9 (2) | 12.9 (2) | 12.9 (2) | 12.9 (2) | 12.9 (2) | 12.9 (2) | 12.9 (2) | 12.9 (2) | ||
| Входная мощность | Hагрев | Ном. | кВт | 2.19 (1) | 2.19 (1) | 2.19 (1) | 2.19 (1) | 2.19 (1) | 2.19 (1) | 2.19 (1) | 2.19 (1) | 2.46 (1) | 2.46 (1) | 2.46 (1) | 2.46 (1) | 2.46 (1) | 2.46 (1) | 2.46 (1) | 2.46 (1) | |
| Охлаждение | Ном. | кВт | 3.47 (2) | 3.47 (2) | 3.47 (2) | 3.47 (2) | 3.47 (2) | 3.47 (2) | 3.47 (2) | 3.47 (2) | 4.34 (2) | 4.34 (2) | 4.34 (2) | 4.34 (2) | 4.34 (2) | 4.34 (2) | 4.34 (2) | 4.34 (2) | ||
| COP | 4.83 (1) | 4.83 (1) | 4.83 (1) | 4.83 (1) | 4.83 (1) | 4.83 (1) | 4.83 (1) | 4.83 (1) | 4.87 (1) | 4.87 (1) | 4.87 (1) | 4.87 (1) | 4.87 (1) | 4.87 (1) | 4.87 (1) | 4.87 (1) | ||||
| EER | 3.22 (2) | 3.22 (2) | 3.22 (2) | 3.22 (2) | 3.22 (2) | 3.22 (2) | 3.22 (2) | 3.22 (2) | 2.98 (2) | 2.98 (2) | 2.98 (2) | 2.98 (2) | 2.98 (2) | 2.98 (2) | 2.98 (2) | 2.98 (2) | ||||
| ГВС | Общие сведения | Гарантированная нагрузка | XL | L | L | XL | L | XL | L | XL | XL | L | L | XL | L | XL | L | XL | ||
| Среднеклимат. условия | Класс энергоэффективности нагрева воды | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Отопление | Среднеклимат. темп. воды на выходе 55°C | Общ. | SCOP | 3.27 | 3.27 | 3.27 | 3.27 | 3.27 | 3.27 | 3.27 | 3.27 | 3.26 | 3.26 | 3.26 | 3.26 | 3.26 | 3.26 | 3.26 | 3.26 | |
| Класс сезонной эффективности отопления помещений | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | ||||
| Среднеклимат. темп. воды на выходе 35°C | Общ. | SCOP | 4.72 | 4.72 | 4.72 | 4.72 | 4.72 | 4.72 | 4.72 | 4.72 | 4.68 | 4.68 | 4.68 | 4.68 | 4.68 | 4.68 | 4.68 | 4.68 | ||
| Класс сезонной эффективности отопления помещений | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||
| Диапазон энергоэффективности | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | ||||
| Примечания | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Условие 1: охлаждение Ta 35°C - LWE 18°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Условие 2: охлаждение Ta 35°C - LWE 7°C (DT = 5°C); нагрев Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | |||||